Flashers
CUBE SOLID STATE, FLASHER, 1 AMP THKA Timers / Flashers THKA timers are solid state output units with digital timing and similar on/off cycle times. The THKA comes in a 2" square case. Ease of installation and hook-up is a primary design benefit. All models with integral time adjustment knob or factory-fixed time require only two connections. They may be wired in-line just like a single pole switch. Units with external time adjustment have two additional terminals for the resistor or potentiometer.
Timing Mode
Application of input voltage to the timer starts the “On” time delay. At the end of the “On” time delay, the “Off” time delay starts. At the end of the “Off” time delay, the load is again energized, the timer returns to the “On” time delay, and the cycling continues as long as input voltage is applied. Removal of the input voltage resets the timer.
Application of input voltage to the timer starts the “On” time delay. At the end of the “On” time delay, the “Off” time delay starts. At the end of the “Off” time delay, the load is again energized, the timer returns to the “On” time delay, and the cycling continues as long as input voltage is applied. Removal of the input voltage resets the timer.
Features:
- Digital timing, solid state output
- 1 Amp current load handling
- 10 Amps single-cycle surge handling
- 4 Overlapping AC voltage ranges (from 19to 277 volts) plus 19-48 VAC/VDC
- ±0.1% Repeat accuracy
- Virtually unlimited time ranges
- Factory-fixed or variable timing adjustment
- Totally encapsulated for protection from harsh environments
- O-ring sealed exposed controls
- Single screw mounting through center mounting hole
- Standard 6.35mm (0.25") quick connect blade terminals
- 100% Operational testing before shipping
- RoHS compliance available
Specifications:
VDC: 19 to 48
Special time ranges available upon request
(optional: ±5%, ±1%)
Variable: -0%, +15%
Limit: -10% at minimum time
Operating: -25°C to +65°C
Transient Protection: 18 joules
Dielectric Strength: 1800V RMS 60Hz
- Input Voltage
VDC: 19 to 48
- Repeat Accuracy
- Time Ranges
Special time ranges available upon request
- Reset/Recycle Time
- Tolerances
(optional: ±5%, ±1%)
Variable: -0%, +15%
Limit: -10% at minimum time
- Recycle Effect
- Temperature Ranges
Operating: -25°C to +65°C
- Life Expectancy
- Protection
Transient Protection: 18 joules
Dielectric Strength: 1800V RMS 60Hz
- Power Requirement
- Weight
- Solid State Output
- Load Current
- Time Cycle Interrupt (Input Voltage Break)