· AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC · Contact arrangement up to 4PDT · Wide selection of termination and mounting styles. · PC terminals available. · Push to test button and indicator lamps. · KUEP incorporates a blow out magnet for high voltage DC switching. · KUIP/KUGP are VDE approved. · Complete line of sockets and DIN rail. · Class B coil insulation. Arrangements: See respective ordering information table. Materials: Fine Silver (5 Amp) silver-cadmium oxide (10 Amp). Gold flash available as standard. Gold diffused and gols alloy on special order. Expected Mechanical Life: CONTACT RATINGS Material Arrangement UL/CSA Ratings Expected Life Fine All 5 amps @ 28VDC or 240VAC Silver 80% PF, 2.5 amp tungsten @ 120VAC, 1/2 amp @ 120VDC 100,000 1/6HP @ 120VAC, 1/3HP @ 240VAC, 5 FLA, 15 LRA @ 250VAC (FLA covered by 30,000 operations). Silver- 1-2 Pole 10 amps @ 28VDC or 240VAC, Cadmium KUP 80% PF, 5 amp tungsten @ Oxide KUIP 120VAC, 3A 600VAC, 1/2 amp KUGP @ 120VDC. 100,000 KUEP 1/3HP @ 120VAC, 1/2HP @ All KUMP 240, 480, and 600VAC, 10 FLA 30 LRA @ 120VAC, 5 FLA, 15 LRA @ 250VAC, (FLA ratings covered by 30,000 operations). KUMP 15 amp @ 277VAC, 80% PF KUM KUMP 100,000 3 Pole 10 amp @ 28VDC or 120VAC KUP 80% PF, 6 2/3 amp @ 240VAC KUIP 80% PF 100,000 4 Pole 10 amp per pole not to exceed 30 amp total @ 28VDC, 120VAC, 80% PF, 6 2/3 amp @ 240VAC, 80% PF 100,000 KUEP SPST-NO 10 amp @ 150VDC KUEP 2PST-NO 5 amp @ 150VDC KUEP 2PDT 3 amp @ 150VDC 100,000 (All other AC ratings apply KUEP) Voltage: From 6 to 110VDC, and 6 to 240VAC Nominal Coil Power: DC Coils: 1.2W - KUP, KUIP, KUMP, 1-3 pole; KUEP, 1 pole. DC Coils: 1.8W - KUP, 4 pole; KUEP, 2 pole; KUGP. AC Coils: 2.0VA - KUP, KUIP, 1-2 pole; KUEP, 1 pole. AC Coils: 2.7VA - KUP, KUIP, 3 pole; KUEP, 2 pole; KUGP, KUMP. DC Volts 1.2 Watt 1.8 Watt Nominal DC Ohms +/-10% Nom. I ma DC Ohms +/-10% Nom. I ma 5 21 238 14 360 6 32.1 187 20 300 12 120 100 80 150 24 472 51 320 75 48 1,800 26.7 1,260 38 110 10,000 11 6,720 16 AC Volts 2VA 2.7 VA Nominal DC Ohms +/-15% Nom. I ma DC Ohms +/-15% Nom. I ma 6 6 335 4.2 460 12 24 168 18 230 24 85 84 72 115 120 2,250 17.5 1,700 24 240 9,110 8.75 7,200 12 Must-Operate Voltage: AC Coil: 85% of nominal voltage or less. DC Coil: 75% of nominal voltage or less. Operating Time (Excluding Bounce): 15 milliseconds, typical, at nominal voltage. Release Time (Excluding Bounce): 10 milliseconds, typical, at nominal voltage. Temperature Range: Operating: Enclosed Relays: -45C to maximum listed in table below. Open Relays: Add 15C to maximum listed. Max C +45C +50C +55C +70C +75C +80C +95C KUP AC DC AC DC 3-4 pole 4 pole 1-2 pole 1-3 pole KUIP AC AC DC 3 pole 1-2 pole 1-3 pole KUGP AC DC 2 pole 2 pole KUEP AC DC AC DC 2 pole 2 pole 1 pole 1 pole KUMP AC AC DC 3 pole 1-2 pole 1-3 pole (approx. 212k .gif @ 750 pixels wide). BUILD YOUR OWN PART NUMBER: KU/KUP, (164K), KUE/KUEP, (91K), KUIP/KUGP, (68K), KUM/KUMP (123K) Graphics (GIF) of Ordering Information. This information will 'build' a part number from a list of available specifications. |
Call: 414-327-1555 Fax : 414-327-0577 Email: indelect@execpc.com Catalog, Quote, Availability. © 2007 Industrial Electronics By Ross LLC |