Industrial Electronics By Ross LLCMilwaukee, Wisconsin US |
|
SDAS-O1 series 1.5 TO 15 AMP AC CURRENT SENSOR · Zero insertion loss · Inductive coupling to power line · Choice of modes - Adjustable overcurrent sensor - Adjustable undercurrent sensor · Solid state sensing circuit · 1 Form C (SPDT) or 2 Form C (DPDT) internal relay Overcurrent sensor - Detects a current in excess of the value determined by the potentiometer setting. A built-in time delay, 200 ms, minimum, allows for normal starting and surge currents. Actual time delay is dependent upon potentiometer setting and magnitude of overcurrent. Any overcurrent lasting longer than this causes the internal relay of the SDAS01 to energize. The relay will remain energized until sensor control voltage is removed, even if the overcurrent ceases to exist. Undercurrent sensor - Reacts to a complete loss of sense current, or any current of less than the potentiometer setting. Upon application of sensor control voltage, there is a nominal 350ms delay during which time power line current must begin. This delay gives line components time to turn on. If, at the end of the delay, sense current should decrease to less than the potentiometer setting of the SDAS-O1 and remain there for approximately 350 ms, the internal relay of the SDAS-O1 will energize. It will remain energized until either sense control current again exceeds the potentiometer setting, or until sensor control voltage is removed. Control Voltage: 24VAC 50/60 Hz./DC +/- 10%. Sense-Current Range: 1.5 to 15 amps AC. Internal Relay Contact Data: 1 Form C (SPDT) type (code X1): 5A @ 28VDC or 2.5A @ 120VAC, res. 2 Form C (DPDT) type (code Y2): 2A @ 28VDC or 1A @ 120VAC, res. Set Point Variation: +/- 25% over operating temperature range. Time Delay: Overcurrent sensor: 200 ms, min., after beginning of overcurrent. Actual delay is dependent upon potentiometer setting and magnitude of overcurrent (see Figure 1). Undercurrent sensor: 350 ms, typ.; 200 ms, min., from beginning of undercurrent after control voltage is applied. Power Requirement: 1.7W or 1.7VA @ 24VAC. Temperature Range: Storage: -40 C to +85 C. Operating: -25 C to +70 C. Enclosure: Plastic dust cover. Mounting: Bracket, socket or printed circuit board options. For sockets see KUP 3 pole sockets. Weight: 3.17 oz. (90 g) approximately. UNDERCURRENT SENSORS Part Number Contacts Mounting SDAS-O1-7Y2B1024 DPDT, 2A DC/1A AC Bracket SDAS-01-7Y2S1024 DPDT, 2A DC/1A AC Socket SDAS-01-7Y2P1024 DPDT, 2A DC/1A AC Printed Circuit SDAS-01-7X1B1024 SPDT, 5A DC/2.5A AC Bracket SDAS-01-7X1S1024 SPDT, 5A DC/2.5A AC Socket SDAS-01-7X1P1024 SPDT, 5A DC/2.5A AC Printed Circuit OVERCURRENT SENSORS Part Number Contacts Mounting SDAS-01-8Y2B1024 DPDT, 2A DC/IA AC Bracket SDAS-01-8Y2S1024 DPDT, 2A DC/1A AC Socket SDAS-O1-8Y2P1024 DPDT, 2A DC/1A AC Printed Circuit SDAS-O1-8X1B1024 SPDT, 5A DC/2.5A AC Bracket SDAS-01-8X1S1024 SPDT, 5A DC/2.5A AC Socket SDAS-01-8X1P1024 SPDT, 5A DC/2.5A AC Printed Circuit (approx. 17K .jpg @ 750 pixels wide). |
Catalog, Quote, Availability. Call:414-327-1555 ,Fax : 414-327-0577 , Email: iebyross@yahoo.com |
©1995-{{date | date:'yyyy'}} Industrial Electronics By Ross LLC ©2003-{{date | date:'yyyy'}} Powered by SYNsCON™.com |