Call:
POTTER & BRUMFIELD KHA series GENERAL PURPOSE DRY CIRCUIT TO 5A MULTICONTACT AC OR DC RELAY File E22575 File LR15734
· Miniature size from 2 pole to 4 pole. A 5 pole version is available as a special order. · KHS hermetically sealed version UL Approved for Class 1 Division 2 hazardous locations. · Various applications include process control, photocopier, and data processing. · Low cost, semiautomated construction.
Arrangements: 2 Form C (DPDT), 4 Form C (4PDT).
Expected Life: 10 million operations, mechanical; 100,000 operations min.
at rated loads. Ratings are based on tests of relays with
ungrounded frames.
Initial Breakdown Voltage: 500V rms, 60 Hz., between open contacts.
1240V rms, 60 Hz., between all other elements.
Contact Resistive Rating
Code Material Minimum Maximum
1 Silver 100mA @ 3A @
12VAC/12VDC 120VAC/28VDC
2* Silver-cadmium 500mA @ 5A @
oxide 12VAC/12VDC 120VAC/28VDC
3 Gold-silver-nickel 10mA @ 2A @
12VAC/12VDC 120VAC/28VDC
4 Palladium 100mA @ 3A @
12VAC/12VDC 120VAC/28VDC
5 Silver alloy 500mA @ 3A @
12VAC/12VDC 120VAC/28VDC
6 Bifurcated cross bar, Dry circuit 1A @
gold overlay silver 120VAC/28VDC
8 Gold diffused silver 50ma @ 3A @
12VAC/12VDC 120VAC/28VDC
Note: Relays should only carry a maximum of 15 amps continuously
for all poles combined. KHS hermetically sealed version maximum rating
is 5A @ 120VAC/28VDC.
Voltage: From 6 to 120V DC, and 6 to 240V AC, 50/60 Hz.
Nom. Power: DC coils - 0.9 watt; 0.5 watt minimum operate @ 25degree C.
AC coils - 1.2 VA; 0.55 VA minimum operate @ 25 degree C.
Max. Power: DC coils - 2.0 watts @ 25 degree C.
Duty Cycle: Continuous.
Initial Breakdown Voltage: 500V rms, 60 Hz.
| DC Coils | AC Coils |
Resistance Nominal Resistance Nominal
Nominal in Ohms Inductance in Ohms AC Current
Voltage +/-10% @ in Henrys +/-15% in mA
25 degree C
5 32 .072
6 40 .08 10.5 200
12 160 .28 43 100
24 650 1.0 160 52
48 2,600 4.5 668 25
90 9,000 13.5
110* 11,000 17.0
120* 13,500 -- 3,900 11.0
240 12,000 6.0
*Note: For 220 and 240VDC, use series dropping 5W resistor of 11,000
ohm.
Must-Operate Voltage: DC: 75% of nominal voltage.
AC: 85% of nominal voltage.
Operate Time: 13 milliseconds typical @ nominal voltage (excluding bounce).
Release Time: 6 milliseconds typical @ nominal voltage (excluding bounce).
Temperature Range: -45 degree C to +70 degree C operate.
-60 degree C to +130 degree C storage.
Mountings: #3-48 stud, sockets with printed circuit or solder terminals,
or bracket plate with #6-32 threaded stud.
Termination: Printed circuit or solder/socket terminals.
Printed circuit terminals are available for KHS on a special
order basis.
Insulating Material: Molded high-dielectric material.
Enclosures: See Ordering Information table.
Cover colors are available in black, red, blue, yellow and
green by special order.
Weight: 1.6 oz. approx. (45 g)
(approx. 83 & 95K .gifs @ 750 pixels wide). BUILD YOUR OWN PART NUMBER: A 75K graphic (GIF) of Ordering Information. This information will 'build' a part number from a list of available specifications. |
![]() |
Call: 414-327-1555 Fax : 414-327-0577 Email: indelect@execpc.com Catalog, Quote, Availability. © 2007 Industrial Electronics By Ross LLC |