Voltage Monitor Relays

VW Series Voltage Band

Macromatic Products Menu :

Voltage Band Relays provide protection to equipment that is required to operate within an upper & lower voltage limit. As long as the operating voltage remains within an OVER & UNDER voltage range, the internal relay stays energized. If the operating voltage falls outside this range, the relay will drop-out.

When nominal operating voltage is applied, the internal relay will energize (Pick-up). If the operating voltage falls outside the preset OVER or UNDER trip points for a period longer than the drop-out time delay (T), the relay will de-energize (Drop-out). When the voltage returns to normal (within the preset OVER & UNDER trip points), the unit automatically resets and the relay energizes. Choose between a unit with fixed drop-out time of 500ms or one with an adjustable 0.5-10 second drop-out time.

Current Monitor Relays CUP Series--Under Current
  • Monitors AC single phase and DC voltages
  • Provides voltage band (window) protection
  • Wide range of user-adjustable Over Voltage and Under Voltage settings
  • Fixed or adjustable time delay on drop-out
  • LED indicates output relay status
  • Compact plug-in case utilizing industry standard 8 pin octal socket
  • 10A DPDT output contacts

Fixed Drop-Out Time Delay (500ms)
NOMINAL VOLTAGE OVER VOLTAGE RANGE UNDER VOLTAGE RANGE PRODUCT NUMBER WIRING/SOCKET
24VAC
120VAC
24-30VAC
102-138VAC
18-24VAC
99-134VAC
VWP024A
VWP120A
8 Pin Octal
70169-D

DIAGRAM 20
12VDC
24VDC
48VDC
110VDC
12-15VDC
24-30VAC
48-60VDC
110-137VDC
9-12VDC
8-24VAC
36-48VDC
83-110VDC
VWP012D
VWP024D
VWP048D
VWP110D

Click here for Sockets & Accessories.


Adjustable Pick-Up & Drop-Out Settings **
Time Delay on Drop-out Fixed at 500ms
NOMINAL VOLTAGE OVER VOLTAGE RANGE UNDER VOLTAGE RANGE PRODUCT NUMBER WIRING/SOCKET
24VAC
120VAC
24-30VAC
102-138VAC
18-24VAC
99-134VAC
VAKP024A
VAKP120A
8 Pin Octal
70169-D

DIAGRAM 20
12VDC
24VDC
48VDC
110VDC
12-15VDC
24-30VAC
48-60VDC
110-137VDC
9-12VDC
8-24VAC
36-48VDC
83-110VDC
VAKP012D
VAKP024D
VAKP048D
VAKP110D




Click here for Sockets & Accessories.



Application Data
Voltage Monitoring Relays can be used as either overvoltage or undervoltage relays, depending on the output contact used:
Voltage Tolerance
+25%/-50% of nominal voltage; AC voltages are 50-60Hz; No supply (input) voltage is required.

Load (Burden): 3VA.

Voltage Settings
Over Voltage: 100-125% of Nominal Voltage
Under Voltage: 75-100% of Nominal Voltage

Temperature: 28o to 65o C (-20o to 150o F)

Indicator LED: Red when Relay is energized and Green when Relay is Off.

Reset: Automatic. Contact Macromatic for information on how to order a unit with Manual Reset.
Response Times:
Operate: 500ms
Release: Fixed 500 ms (VWP Series)
Adjustable 0.5 -10 Seconds (VWKP Series)

Output Contacts: DPDT 10A Resistive @240VAC/30VDC, 1/2HP @240VAC

Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations