Welcome to World Headquarters of Macromatic-Offering Time Delay Relays, Alternating Relays & Protective Relays

Welcome to the Electronic Supplies by Industrial Electronics By Ross LLC

Electronic Supplies by Industrial Electronics By Ross LLC in Wisconsin reader of Electronic Components Potter Brumfield P&B Relays Fluke

Industrial Electronics By Ross LLC

Electronic Supplies by Industrial Electronics By Ross LLC in Wisconsin reader of Electronic Components Potter Brumfield P&B Relays Fluke
Call: 414-327-1555
Fax : 414-327-0577
Email: indelect@execpc.com
OR, use our handy short
Form.
Catalog, Quote, Availability.


Time Delay Relays

Time Ranger ™ Programmable Multi-Range Plug-in

Macromatic Products Menu :
Single-Knob
Dual-Knob
  • Each unit has 16 timing ranges built-in
  • Selecting a range is easy using a rotary switch (no math is required or DIP switches to set)
  • Timing ranges up to 2 hours (single knob units) or 24 hours (dual knob units)
  • Independently selectable & adjustable ON & OFF times on dual knob timers
  • Uses industry-standard 8 or 11 pin octal sockets
  • 10A DPDT output contacts
  • with appropriate socket

Single Knob Units (0.1 Sec - 2 Hr)
FUNCTION INPUT VOLTAGE PRODUCT NUMBER
Complete Product Number
Using 2 Digit Code From
Table at Left
WIRING/SOCKETS
ON DELAY 120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60222
TR-60226
TR-60228
TR-60221
8 PIN OCTAL
70169-D

DIAGRAM 1
INTERVAL ON 120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60522
TR-60526
TR-60528
TR-60521
FLASHER 120VAC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60822
TR-60826
TR-60828
TR-60821
OFF DELAY
Control Switch Trigger
120VAC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61622
TR-61626
TR-61628
TR-61621
11 PIN OCTAL
70170-D

DIAGRAM 2
SINGLE SHOT
Control Switch Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61522
TR-61526
TR-61528
TR-61521
WATCHDOG
(Retriggerable
Single Shot)
Control Switch Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61322
TR-61326
TR-61328
TR-61321
OFF DELAY
Power Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61922
TR-61926
TR-61928
TR-61921
11 PIN OCTAL
70170-D

DIAGRAM 4
SINGLE SHOT
Power Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61722
TR-61726
TR-61728
TR-61721
WATCHDOG
(Retriggerable
Single Shot)
Power Trigger
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61822
TR-61826
TR-61828
TR-61821

Click here for Sockets & Accessories.
Timing Ranges

Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top:

Single Knob Units
Time Delay Dial Setting
0.1 - 0.25 Sec.
0.2 - 0.5 Sec.
0.3 - 1 Sec.
0.5 - 2 Sec.
1 - 4 Sec.
2 - 8 Sec.
4 - 15 Sec.
8 - 30 Sec.
15 - 60 Sec.
30 - 120 Sec.
1 - 4 Min.
2 - 8 Min.
4 - 15 Min.
8 - 30 Min.
15 - 60 Min.
30 - 120 Min.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P


Dual Knob Units (0.6 Sec - 24 Hr)

FUNCTION INPUT VOLTAGE PRODUCT NUMBER
Complete Product Number
Using 2 Digit Code From
Table at Left
WIRING/SOCKETS
REPEAT CYCLE
(OFF Time First Followed by ON
Time and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-63122
TR-63126
TR-63128
TR-63121
8 PIN OCTAL
70169-D

DIAGRAM 1
REPEAT CYCLE
(ON Time First Followed by OFF
Time and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-65122
TR-65126
TR-65128
TR-65121
DELAYED INTERVAL
(OFF Time Followed by ON
Time Followed by OFF Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-66122
TR-66126
TR-66128
TR-66121
DELAYED INTERVAL
Control Switch Trigger
(OFF Time Followed by ON
Time Followed by OFF Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-66522
TR-66526
TR-66528
TR-66521
70170-D

DIAGRAM 2
Dual Knob Units
Timing Range Dial Setting
0.6 - 2.5 Sec.
1.5 -5 Sec.
2.5 - 10 Sec.
5 - 21 Sec.
10 - 42 Sec.
0.4 - 1.4 Min.
0.7 - 2.8 Min.
1.5 - 5.5 Min.
3 - 11 Min.
5.5 - 22.5 Min.
11 - 45 Min.
0.4 - 1.5 Hr.
0.8 - 3 Hr.
1.5 - 6 Hr.
3 - 12 Hr.
6 - 24 Hr.
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P


Application Data

Application Data
Voltage Tolerance
AC Operation: +10/-15% of nominal at 50/60 Hz.
DC Operation: +10/-15% of nominal.

Load (Burden)
2 VA

Setting Accuracy:
Maximum Setting: +5%, -0%
Minimum Setting: +0%, -50%

Reset Time:
On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds
Off Delay/Single Shot/Watchdog: 0.04 Seconds

Repeat Accuracy: (constant voltage & temperature):
> 2 Seconds Delay +0.1%
0.1 - 2 Seconds Delay +2%

Start-up Time:
(Time from when power is applied until unit timing)
120 & 240V Units: 0.05 Seconds
12, 24 & 48V Units: 0.08 Seconds

Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units.

Temperature:
12-120V Input Voltage: -28o to 65oC (-20o to 150oF)
240V Input Voltage: -28o to 50oC (-20o to 122oF)

Response Times:
Power Up: 2 seconds fixed delay
Operate: Adjustable from 0.1 - 10 Seconds
Release: Adjustable from 0.1 - 10 Seconds

Indicator LED: Red Steady when Relay is energized; Green Steady when Relay is Off; and Green Rapid Flashing when in power-up mode time delay.

Reset: Automatic

Approvals:

Dimensions


Macromatic

Catalog, Quote, Availability.
Call: 414-327-1555 ,Fax : 414-327-0577 , Email: indelect@execpc.com

©1995-2006 Industrial Electronics By Ross LLC
©2003-2006 SEO by synscon.com
Search Engine Marketing Company