Alternating Relays

For 1 or 2 Switch Applications

Macromatic Products Menu :

Alternating Relays are used in duplex control (pump control) applications where the optimization of load usage is required by equalizing the run time of two loads. They are also used where additional capacity is required in case of excess load requirements. This alternating action is initiated by a control switch, such as a float switch, manual switch, timing relay, pressure switch, or other isolated contact. Each time the initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay.

Alternating Relays are available in three output configurations: SPDT, DPDT and DPDT cross-wired. See "Typical Installations" below for more information.

Each version is available with an optional three position selector switch. This allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the Alternating Relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. The selector switch has a low profile to prevent any accidental changes in status.

  • For Duplex Control (Pump Control)
  • Control Voltages of 12, 24, 120 & 240VAC
  • Compact plug-in case utilizing industry-standard 8 or 11 pin octal sockets
  • Three 10A output contact configurations: SPDT, DPDT, or DPDT Cross-Wired
  • Optional low profile selector switch to lock in one sequence
  • 2 LED's indicate relay status
  • with socket

OUTPUT CONTACTS CONTROL VOLTAGE PRODUCT NUMBER WIRING/ SOCKET
SPDT
w/o Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A6
ARP024A6
ARP120A6
ARP240A6
8 Pin Octal
70169-D
DIAGRAM 17
SPDT
w/ Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A6R
ARP024A6R
ARP120A6R
ARP240A6R
DPDT
w/o Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A2
ARP024A2
ARP120A2
ARP240A2
8 Pin Octal
70169-D
DIAGRAM 17
DPDT
w/ Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A2R
ARP024A2R
ARP120A2R
ARP240A2R
DPDT CROSS-WIRED
w/o Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A3
ARP024A3
ARP120A3
ARP240A3
8 Pin Octal
70169-D
DIAGRAM 17
DPDT CROSS-WIRED
w/ Selector Switch
12VAC
24VAC
120VAC
240VAC
ARP012A3R
ARP024A3R
ARP120A3R
ARP240A3R

Click here for Sockets & Accessories.




Application Data

Voltage Tolerance: +10%/-15% of control voltage at 50/60hz.
Load (Burden): 3VA.

Output Contacts:
DPDT 10A Resistive @240VAC/30VDC, 1/2HP @240VAC

Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations

Temperature:
-28o to 65oC (-20o to 150oF)

Transient Protection: 10,000 volts for 20 microseconds

Indicator LED's: 2 LED's marked LOAD A and LOAD B

Optional Selector Switch Settings:
ALTERNATE
LOAD A
LOAD B

Approvals:

with socket

Dimensions


Typical Installations

The loads in the following examples could be pumps, compressors, or air conditioning/refrigeration units:

SPDT & DPDT

In the off state, the Control Switch is open, the Alternating Relay is in the LOAD A position, and both loads (M1 & M2) are off. When the Control Switch closes, it energizes the first load (M1). The red LED marked "LOAD A" glows. As long as the Control Switch remains closed, M1 remains energized. When the Control Switch opens, the first load (M1) is turned off and the Alternating Relay toggles to the LOAD B position. When the Control Switch closes again, it energizes the second load (M2). The red LED marked "LOAD B" glows. When the Control Switch opens, the second load (M2) is turned off, the Alternating Relay toggles back to the LOAD A position, and the process can be repeated again. On relays with DPDT contacts, two pilot lights can be used for remote indication of LOAD A or LOAD B status.

DPDT Cross-Wired

In the off state, both the Lead Control Switch and the Lag Control Switch are open, the Alternating Relay is in the LOAD A position, and both loads are off. When the Lead Control Switch closes, it energizes the first load (M1). The red LED marked "LOAD A" glows. As long as the Lead Control Switch remains closed, M1 remains energized. If the Lag Control Switch closes, it energizes the second load (M2). When the Lag Control Switch opens, the second load (M2) is turned off. When the Lead Control Switch opens, the first load (M1) is turned off and the Alternating Relay toggles to the LOAD B position. When the Lead Control Switch closes, it turns on the second load (M2). The red LED marked "LOAD B" glows. If the Lag Control Switch closes, it will energize the first load (M1). When the Lag Control Switch opens, the first load (M1) is turned off. When the Lead Control Switch opens, the second load (M2) is turned off, the Alternating Relay toggles back to the LOAD A position, and the process can be repeated again. NOTE: if the Lag Control Switch does not close while the Lead Control Switch is closed, the Alternating Relay will act as a normal unit.