Description: Advanced protection Class RK1 current-limiting, fast-acting fuses.
Catalog Symbol: KTS-R-(amp)
Ratings:
Catalog Symbol: KTS-R-(amp)
Ratings:
Volts: 600Vac
Amps: 1-600A
IR: 200kA Vac RMS Sym.
Agency Information:
CE, UL Listed, Std. 248-12, Class RK1, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787
Dimensions – in
Amps: 1-600A
IR: 200kA Vac RMS Sym.
Agency Information:
CE, UL Listed, Std. 248-12, Class RK1, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-02, File 53787
Dimensions – in
Catalog Numbers (amps)
KTS-R-1 | KTS-R-20 | KTS-R-80 | KTS-R-275 |
KTS-R-2 | KTS-R-25 | KTS-R-90 | KTS-R-300 |
KTS-R-3 | KTS-R-30 | KTS-R-100 | KTS-R-350 |
KTS-R-4 | KTS-R-35 | KTS-R-110 | KTS-R-400 |
KTS-R-5 | KTS-R-40 | KTS-R-125 | KTS-R-450 |
KTS-R-6 | KTS-R-45 | KTS-R-150 | KTS-R-500 |
KTS-R-8 | KTS-R-50 | KTS-R-175 | KTS-R-600 |
KTS-R-10 | KTS-R-60 | KTS-R-200 |
Carton Quantity and Weight
Amp Rating | Carton Qty. |
1–30 | 10 |
40–60 | 10 |
70–100 | 1 |
110–200 | 1 |
225–400 | 1 |
450–600 | 1 |
Features:
• Single-element, fast-acting fuses with minimal time-delay
• Provides a high degree of short-circuit current-limitation (component protection)
• Particularly suited for circuits and loads with no heavy surge currents of motors, transformers, solenoids, and welders
• Commonly used to protect circuit breakers with lower interrupting ratings.
• If used in circuits with surge currents (motors, etc.) must be sized to prevent unwanted opening. It is recommended to use an ultimate protection Low-Peak™ LPS-RK time-delay fuse for inductive load applications.
• Incorporate Class R rejection feature. Can be inserted in non-rejection type fuse holders to physically and electrically replace fast-acting Class H, K1, K5, RK5, and other fastacting fuses.
• Provides a high degree of short-circuit current-limitation (component protection)
• Particularly suited for circuits and loads with no heavy surge currents of motors, transformers, solenoids, and welders
• Commonly used to protect circuit breakers with lower interrupting ratings.
• If used in circuits with surge currents (motors, etc.) must be sized to prevent unwanted opening. It is recommended to use an ultimate protection Low-Peak™ LPS-RK time-delay fuse for inductive load applications.
• Incorporate Class R rejection feature. Can be inserted in non-rejection type fuse holders to physically and electrically replace fast-acting Class H, K1, K5, RK5, and other fastacting fuses.
Recommended Fuse Blocks
Fuse Amps | 1-Pole | 2-Pole | 3-Pole |
0-30 | R60030-1 | R60030-2 | R60030-3 |
35-60 | R60060-1 | R60060-2 | R60060-3 |
70-100 | RM60100-1CR | RM60100-2CR | RM60100-3CR |
110-200 | RM60200-1CR | RM60200-2CR | RM60200-3CR |
225-400 | RM60400-1CR | RM60400-2CR | RM60400-3CR |
450-600 | RM60600-1CR | RM60600-2CR | RM60100-3CR |
Fuse Reducers For Class R Fuses
Equipment Fuse clips | Desired Fuse (Case) Sizez | Cataloge Numbers(Pairs) |
60A | 30A | NO.663-R |
100A | 30A | NO.216-R |
60A | NO.616-R | |
200A | 60A | NO.626-R |
100A | NO.2621-R | |
400A | 100A | NO.2641-R |
200A | NO.642-R | |
600A | 100A | NO.2661-R |
200A | NO.2662-R | |
400A | NO.2664-R† |
† Single reducer only (pair not required).
Time-Current Curves - Average Melt
Current-Limitation Curves